Reading an EPANET input file produces a model for water distribution. It shares its lexical tokenizer (noodl.apps.inpfile) with the SWMM reader; each format's own section names, column layouts and units are read by apps/water/inp.py.

Read: [JUNCTIONS], [RESERVOIRS], [TANKS], [PIPES], [PUMPS], [VALVES], [DEMANDS], [PATTERNS], [CURVES], [CONTROLS], [OPTIONS], [TIMES].

Ignored because nothing in the hydraulics references them: [TITLE], [REPORT], [COORDINATES], [VERTICES], [LABELS], [BACKDROP], [TAGS], [ENERGY], [END], and the quality sections (a quality run is configured through build_model(quality=...) instead).

Aggregated / interpreted: several [DEMANDS] categories of one junction add up (they replace the [JUNCTIONS] demand); categories with different patterns are refused (a category with no pattern uses the default pattern, so it equals one naming that default explicitly), since one demand pattern per junction is modelled. [TIMES] values take an optional unit (any token beginning SEC, MIN, HOU or DAY, case-insensitive, as EPANET reads it: MINS, SECS, HOU; a bare number is hours, HH:MM[:SS] is a clock time); other units are refused.

Refused by name: [RULES]; [EMITTERS]; [STATUS] with content; time-based controls (only LINK <id> OPEN|CLOSED IF NODE <tank> BELOW|ABOVE <level> is read); PRV and PSV valves; a constant-power pump; a pump with a speed pattern; a tank with a volume curve; a HEADLOSS other than H-W or D-W; a closed pipe or check valve.

A constant-power pump is refused with a specific reason: the head-flow relation EPANET uses internally for one is not stated in the manual, so implementing it would be a guess.

Units follow [OPTIONS] UNITS: CFS GPM MGD IMGD AFD are US, LPS LPM MLD CMH CMD are SI, and everything is converted to SI on read. D-W roughness is millimetres (SI) or millifeet (US). A VISCOSITY above 1e-3 is a multiplier on water's viscosity, anything else the actual kinematic viscosity (m²/s or ft²/s), as in EPANET. A HEADLOSS D-W file is modelled with EPANET's own composite friction law by default (see Darcy-Weisbach). Unrecognised [OPTIONS] lines are recorded verbatim in notes["unrecognised_options"] rather than dropped.

from noodl.apps.water import read_epanet_inp, build_model, water_steady

net = read_epanet_inp("twoloop_si.inp")
model, state, drivers = build_model(net)
final = water_steady(model, state, drivers)

# final["water.phi"] is head (m) at every node
# final["water.q"] is flow (m3/s) in every link