CONTAM (.prj, .wth, .ctm)

Reading a CONTAM project, weather file and ambient-concentration file produces a model for building physics. Each .prj airflow-path component becomes one of the noodl.elements objects the building application assembles into a network by hand; a source/sink record becomes one of the source and sink models in noodl.apps.building_physics.sources.

CONTAM .prj

read_prj(path) -> Project parses a documented subset of TN 1887r1 Appendix A into a Project, building a float64 Network, its elements and its drives. project_to_model(project, *, ambient=None, species=True, scheme="implicit") returns (model, state, drivers).

Supported: run control (Project.run_control, a RunControl: the steady simulation's date and time, the transient run's start and end date and time, time step and output step, day type, the weather and contaminant file names, and dodMdt) and ambient conditions; the simulated species' records (Project.species_records: molar mass, mean diameter, effective density, diffusivity, default concentration; the decay constant is read but, as in ContamX, not applied; a nonzero one raises a ContamCompatibilityWarning, which warnings.filterwarnings("ignore", category=ContamCompatibilityWarning) silences) and each species' default ambient concentration (Project.ambient_mass_fractions); kinetic reactions on zones (Project.zone_reactions, the species layer's kinetics); day and week schedules referenced by zones (the zone temperature, on "T") and by paths (a flow multiplier, through Scaled on "flow_multiplier.<kind>") and by sources and sinks (a multiplier of the whole source or sink, on "species.source_multiplier"; for ccf, cut, prs, dvs and drs records); wind pressure profiles with the linear or cubic-spline curve fit (WindProfile(..., curve="linear" | "spline"); the spline is periodic in the wind angle, as ContamX evaluates it), and a constant wind pressure on an envelope path ("wind_pressure.<kind>", positive pushing air from ambient into the zone, as ContamX); zones and initial concentrations; airflow paths; the power-law element family (plr_orfc/leak1/leak2/leak3/crack/fcn/test1/test2/conn/stair/shaft/qcn), the quadratic family (qfr_*), doorways (dor_door, dor_pl2), dampers (plr_bdq, plr_bdf), constant-flow fans (fan_cmf, fan_cvf), the cubic-spline elements (csf_fsp, csf_qsp, csf_psf, csf_psq; a curve whose fitted spline overshoots and so is not increasing is refused, though ContamX may accept it, because the inversion of the pressure-against-flow forms would be ambiguous), and the cubic fan (fan_fan) with its speed schedule (the speed ratio, by the fan laws), its path mult (fans in parallel), the rating density and the shut-off orifice below its off ratio; source/sink elements ccf, cut, eds, brs, prs, dvs, drs, plm and pkm, attached by project_to_model (scaled by the record's multiplier, which enters the element's first coefficient, and a ccf record's removal coefficient too); filters on airflow paths (Project.edge_filters, the species layer's transmission): constant-efficiency (cef), particle (pf0, interpolated at each species' mean diameter as ContamX does), super (spf) and Penn State UVGI (uv1) filter elements; a filter acts on the air crossing its path in either direction; a UVGI filter (UVGIFilter, on a path; its 14 values, which ContamX reads as one stream whatever the line breaks, are the design survivability, velocity, mass flow and rate constant, the age-model flag, C0..C4, K0, K1 and two display units) acts on each species by its UV susceptibility (the species record's Kuv), with a dose that follows each airflow solve's flow and the upstream temperature and density and, with the age model, the time, so project_to_model writes the species layer's transmission with a FilterTransmission closure and iterates each step (coupling="iterate") on that step's own flows; duct networks: duct elements dct_dwc (ContamX's friction law; its lam field has no effect, as in ContamX), dct_plr, dct_fcn, dct_qcn, dct_cmf, dct_cvf, dct_fan, dct_bdq, dct_bdf, dct_fsp, dct_qsp, dct_psf, dct_psq; junctions with their temperatures and initial concentrations and ContamX's volumes (half the length times the element area of every segment that meets them; a junction without volume, whose segments all have zero length, holds no air and carries the mix of what flows through it); terminals with their loss and balance coefficients (the duct-balancing data bal, Fdes and Cbmax is read and, as in ContamX, has no effect), filters, schedules (the opening, or the junction temperature when the week schedule's unit type is a temperature) and wind (an ambient terminal whose flags carry the value 1, from its profile or a constant wind pressure); segments with their dynamic losses, filters and schedules (a flow multiplier, or a fan's speed ratio); simple air-handling systems (Project.closures, one AirHandlerFlows per system, on the edge kind ahs_<nr>): their plenum zones (zero gauge pressure in the airflow solve, Project.flow_balanced; storage-free when their volume is 0, Project.storage_free), supply and return points with their design flows, schedules (on "flow_multiplier.ahs_<nr>") and filters, the recirculation, outdoor-air and exhaust paths with their filters, the outdoor-air fraction schedule (on "outdoor_air_fraction.ahs_<nr>") and the minimum outdoor-air flow (both read from the recirculation path, as ContamX reads them; ContamX finds the implicit paths by their flags, not by the numbers in the AHS record, which noodl checks against them); control nodes: sensors (sns: zone and junction mass fraction, temperature and gauge pressure; path, duct segment and terminal flow and pressure difference; with their offset, scale and time constant), schedule (sch), constant (set), pass and report (pas, log), arithmetic (add, sub, mul, div, sum, avg, max, min, abs), logic (bin, inv, and, or, xor), limit switches and limit controls (lls, uls, lbs, ubs, llc, ulc), hysteresis (hys), proportional and PI control (pc1, pi1); control references on zones (temperature), paths, sources, duct segments, terminals and AHS paths, acting on what a schedule there acts on and taking precedence over it. When some record references a control node, the nodes that an actuator or a named report node (a pas node with a name, which ContamX reports through its API) depends on become a sampled ControlNetwork, first among the model's closures; project_to_model builds a new one for every model, and simulate_project(...)["control"] returns the named report nodes' values in node order. A project whose control nodes only report (no record references one) builds no network and returns no "control", so it loads and runs, steady runs included, as without them. Occupancy schedules and exposures (Project.occupants, one Occupant named "occupant <nr>" per exposure record): the occupant's zone by day type, from the listed time exactly (a move in the middle of a step splits the step there), out of the building on zone 0, and its generation, cgmax (kg/s per person) times cgmlt (people) times its week schedule at the step's end, split between zones by the time spent in each and nothing while out; an exposure record whose generation flag is 0 generates nothing, whatever generation lines it lists. project_to_model attaches an OccupantGeneration for the occupants that generate, and simulate_project(...)["exposure"] is ContamX's exposure file: each occupant's step-mean mass fraction of the zone it occupies, zero while out. The occupants' coordinates (X Y relHt, which only place an occupant in a 1-D zone), the unit fields and the fifth field of an exposure record (ContamX needs it and ignores its value) are read and ignored. The zone flag value 16 leaves a zone out of the building volume (the node attribute in_building_volume, 0 for such a zone). Project.building_zones is ContamX's conditioned space, the default of building_air_change_rate: every zone without that flag, the air handlers' plenums and the duct junctions (measured on ContamX 3.4.1.7: the .ach header's volume includes the plenums and the junctions' duct volume, and a flow between a junction and a zone stays inside the space).

Refused by name, rather than silently dropped: a control node of another type (mod, int, rav, dls, dlx, cvf, dvf, phantom nodes) when an actuator, or a named report node of a project with actuators, depends on it (unused nodes of any known type are ignored); a super node (sup, whose sub-nodes the reader cannot lay out) and a control node type the reader does not know at all (its data layout is unknown), wherever they are; a reference to a node the file does not define; occupancy and exposure sensors, and a sensor of a species the model does not carry; a flow or pressure-difference sensor on a doorway (two-way path); a control on a duct junction that is not a terminal, on a triggered (eds, brs, plm, pkm) source, on a Darcy-Colebrook segment or on an AHS outdoor-air or exhaust path; control references in a steady airflow run (simulate_project); boundary-layer diffusion (bls), resuspension (dvr) and super (sup) source/sink elements, when a source/sink record references one; a source/sink record whose element or zone the file does not define; gaseous (gf0) filter elements, referenced or not; a UVGI filter element whose age-model flag is not 0 or 1 or whose record does not hold exactly 14 values, and a UVGI filter on a duct segment or terminal (not measured against ContamX) or on a path modelled as more than one opening (a doorway: the dose needs the path's one flow); a filter that names a species the project does not simulate (when a path references it: an unreferenced filter element is read and unused), a super filter that contains itself, and a path whose filter number the file does not define; non-trace species; a contaminant list that is not the simulated species in file order; a source or kinetic reaction that names a species the project does not simulate (a species the file defines but marks as not simulated included), a kinetic reaction that gives one product-reactant pair twice, and a zone whose kinetic reaction number the file does not define; a schedule number that no week schedule carries; a week schedule that names a day schedule the file does not define; a schedule on an eds, brs, plm or pkm source (CONTAM triggers these once, at the schedule's first nonzero value); a zone without the variable-pressure flag (which ContamX holds at constant pressure), unless an air-handling system names it as a plenum, or, in a project with species, without the variable-contaminants flag (ContamX then holds the zone's concentrations at their initial values and ignores its sources); CFD and 1-D convection/diffusion zones; continuous-values-file zones and paths; duct elements of any type not listed above; duct leakage (a duct element's leakage rate); a schedule on a Darcy-Colebrook segment (ContamX ignores it); kinetic reactions or value files on junctions, and value files on segments; a segment, junction or terminal that references a junction, duct element, level or zone the file never defines; wind data on a terminal that is not an ambient terminal whose flags carry the value 1; a junction type other than 0 (junction), 1 or 3 (terminal); a non-temperature schedule on a junction that is not a terminal; a junction that no segment or terminal reaches; initial-concentration rows for a zone or junction the file does not define; a duct network with densZP = 1 or dodMdt = 1 (the junctions' air mass under either is unmeasured); an air-handling system record that disagrees with its paths' flags and endpoints, implicit air-handling paths that are not the last paths or not in the order of the air-handling records (ContamX gives the k-th record the k-th recirculation, outdoor-air and exhaust path, and mis-assigns them otherwise; this also refuses an implicit path named by two records), a path that is both an implicit air-handling path and a supply or return point, a supply or return point without an air-handling system or naming one the file does not define, or whose path neither leaves that system's supply zone nor enters its return zone, a schedule or a flow on an outdoor-air or exhaust path or a mult on a supply or return point (ContamX ignores them), a flow element or a wind pressure on an air-handling path, a kinetic reaction in a zero-volume plenum, any other path or duct terminal joined to a plenum (only the air handler's own flows may touch it), an air-handling system with densZP = 1, and a steady contaminant run with an air handler off (nothing passing through a plenum); a zone or junction with species rows that no airflow path, duct segment or terminal reaches (it would have no species state); airflow modes other than steady and transient (duct balancing, the building airflow and pressurization tests); a constant wind pressure on an interior path; sup_afe super elements (ContamX 3.4.1.7 cannot simulate them); stackD = 1 (densities varying with height inside a zone); a wind pressure profile with the trigonometric curve fit; a day schedule whose shape is neither rectangular nor trapezoidal; zone names with spaces; an occupancy schedule number given twice, an occupancy point line that is not hh:mm:ss zone X Y relHt, and an occupancy schedule that does not run from 00:00:00 to 24:00:00 (ContamX stops on one that does not end there during the run) or that places an occupant in a zone the file does not define; an exposure record with four fields (ContamX refuses it), exposures not numbered 1, 2, ... in file order, an exposure that does not list 12 occupancy schedules (one per day type), a malformed generation line, and an exposure that names an occupancy or week schedule the file does not define, generates a species the project does not simulate or reads its generation from a value file; an occupant in the ambient, a zone no airflow path reaches or a zero-volume plenum (project_to_model, whether it generates or only breathes); occupants in a run whose contaminant simulation is not transient or that simulates no species (simulate_project; their generation and exposure need both). A project with occupants whose run control simulates no contaminants still loads: project_to_model builds its airflow and leaves the occupants out.

Control nodes that nothing uses are read but not built: NIST's own sample projects carry dozens of unreferenced sensor and logger nodes (integrations among them), and those projects must load.

How ContamX evaluates controls (measured against ContamX 3.4.1.7), and so noodl: once per time step, before the step's airflow, from the state the step starts from (and once before the initial airflow). Flow, pressure-difference and gauge-pressure sensors read 0 at that first evaluation, then the last airflow solve; a mass-fraction sensor reads the initial mass fraction. A temperature sensor sees a scheduled or controlled temperature one step late (the value the previous step used). The nodes are evaluated in the file's sequence order (seq); a node whose input comes later in that order reads the input's previous value, 0 before the first evaluation, except a constant (set), whose value ContamX presets. A schedule node takes its schedule's value at the step's end, as a schedule on a record does, so a control through a schedule node is the same schedule attached directly. A control value on a path is not clipped: 2 doubles the flow, -0.5 reverses it. A division by zero stops ContamX, and noodl raises naming the node.

How ContamX evaluates a UVGI filter (measured against ContamX 3.4.1.7), and so noodl: the efficiency is 1 - exp(-k I_t) with the dose I_t of TN 1887r1 (equations uv-1 to uv-9), the temperature and density those of the path's from-zone, the velocity the path's mass flow over that density and the area F_design / (1.2041 u_design), and the age t in hours since the start of the run. The lamp output OUT_TU is clamped to 0..100 % (a negative one inactivates nothing). The age factor (K0 + K1 ln t) / 100 is capped at 1, which holds it at 1 until t_100 when K1 < 0 and makes it K0 / 100 from the first step when K1 = 0; a negative age factor becomes 0.1. Air crossing a UVGI filter against its path's direction gets a fixed dose of 1 J/m2, whatever the filter's data (even with no lamp output): efficiency 1 - exp(-k). That is ContamX's fallback, not the Penn State model; noodl follows it, with one ContamCompatibilityWarning per filter the first time it happens.

project_to_model never builds a thermal layer, because a .prj carries no thermal data. A run control that simulates no contaminants (none) builds no species layer and binds no source inputs.

project_to_model returns drivers at the steady-simulation instant of the run control (its day, time and day type), so a steady() on them is CONTAM's steady simulation, schedules included. Project.inputs holds the schedules as Inputs for simulate.

Every power-law element is built as UpstreamDensityPowerLaw — re-evaluating the density of the air entering the path, per direction, matching ContamX section 3.2. The cubic fan (fan_fan) runs at the ratio of its upstream density to its rating density by the fan laws, and its shut-off orifice takes the upstream density too. The quadratic, damper and constant-flow fan families keep reference-density coefficients, because they are not part of this application's parity evidence.

Node densities are computed every step by the PrescribedTemperatureDensity closure from two drivers: "T" (K, every node's temperature, the ambient's included) and "P_ref" (Pa, the barometric pressure). The species layer's capacity is each zone's air mass at that density, rho V, as ContamX holds it. A scheduled zone temperature or a weather file therefore changes both from step to step. When the run control sets densZP = 1, ContamX evaluates each zone's density at its absolute pressure Pb + P_zone. project_to_model then adds a ZonePressureDensity closure that does the same from the previous solve's pressures, zone air masses included. When the run control sets dodMdt = 1, each zone's air-mass change over a step enters its airflow balance (simulate switches the term on by default for such a model), and ContamX takes that mass at the zone's absolute pressure even with densZP = 0. project_to_model therefore attaches a ZoneAirMassChange node source to the air layer (only when the run control sets dodMdt and a zone has volume), which acts only when simulate supplies the step's start mass. For a dodMdt project with species it also adds a ZonePressureDensity(densities=False) closure, which scales the species layer's capacity (the zone air mass) and leaves the densities at Pb. Whenever the model carries a ZonePressureDensity closure, prj.steady(model, state, drivers) repeats model.steady to the pressure fixed point, and so does each step of simulate; they do the same for a closure that reads the solved pressure (a pressure-driven source); otherwise it is a single call. The zone-pressure density term is small in the density (|P_zone| / Pb, ~1e-5) but a stack flow is driven by a density difference, which amplifies it: on a 20 K stack it is 4e-5 of the flow.

from noodl.apps.building_physics import read_prj, project_to_model
from noodl.apps.building_physics.prj import steady

project = read_prj("valThreeZonesWthCtm-UseApi.prj")
model, state, drivers = project_to_model(project)
solved = steady(model, state, drivers)

flows = project.path_flows(solved["air.q"])   # in CONTAM path-number order

simulate_project(project) runs the project the way ContamX does: its run control (start, end and time step), its schedules, and the weather and ambient-concentration files it names (resolved next to the .prj). Every input is evaluated at the end of each step, with no step split at a schedule's jump, and the zone air-mass change enters the airflow balance when the run control sets dodMdt = 1. A step whose airflow solve does not converge from the previous step's pressures is retried once from the linear initial guess (diagnostics={} lists such steps under "airflow_retries"). A steady-airflow run returns the one steady state at the run control's steady instant. Cyclic contaminant runs, integration other than the trapezoid method with weight 1 (implicit Euler), steady airflow with transient contaminants, transient airflow with steady contaminants (ContamX solves those to steady state at every step), and a run that is not a whole number of time steps are refused by name.

project = read_prj("test_OneZoneWthCtmStack.prj")
out = simulate_project(project)          # the project's run control, schedules, .wth and .ctm
out["path_flow"]                         # (289, 2) kg/s, path-number order

A project with a duct network adds its junctions to the network as nodes named "junction <nr>" (Project.junctions), after the zones: the species state carries the zones' rows first and the junctions' after them, and project.zone_mass_fractions(x) selects the zones. project.terminal_flows(q) is the flow out of each duct terminal into its zone, in junction-number order (the order and sign of ContamX's getDuctTerminalFlow), and project.segment_flows(q) the flow along each segment in segment-number order. simulate_project and contamx.run_project both report "terminal_flow", (N, n_terminals) kg/s; run_project's is empty, (N, 0), without terminals. When the project's output flags ask for them, run_project also returns what ContamX writes to its exposure, age-of-air and air-change files (.ebw, .age, .ach), one row per step: "exposure" (N - 1, n_exposures, K) kg/kg, "age" (N - 1, n_zones) in hours, "air_change_rate" (N - 1,) 1/h (the total column) and "building_volume" (m³, the conditioned volume of the .ach header). A result file that is empty or truncated, or whose columns disagree with its header, is refused by name; result files left next to the project by an earlier run are not copied into the scratch directory, so only this run's are read.

CONTAM .wth

read_wth(path) -> Weather reads the WeatherFile ContamW 2.0 format. Date, Time, Ta, Pb, Ws, Wd drive the model, and Hr (g/kg) is stored as humidity_ratio in kg/kg. The per-day rows give each day's day type, which selects the day schedules of the week schedules; Weather.day_types maps the day of the year to it, and a Calendar(day_types=...) uses it. Radiation and ground-temperature columns are ignored.

weather = read_wth("year.wth")
drivers.update(weather.drivers_at(t, thermal="thermal"))

at(t) interpolates linearly between listed times, with wind direction interpolated on its shortest arc. drivers_at(t) returns the driver keys a build_model-built model reads: "<thermal>.x_boundary", "P_ref", "V_met", "theta_w". It handles the single-boundary-node case; a model with several prescribed temperatures must build its own boundary vector.

Weather.inputs(model) writes the weather into a model's drivers at every step of simulate: the ambient entry of "T" on the CONTAM route, or every boundary temperature of a thermal model, plus P_ref, V_met and theta_w. Weather.signal("Ta") is one column as a signal. A run outside the file's rows raises.

CONTAM .ctm

read_ctm(path) -> AmbientConcentrations reads the SpeciesFile ContamW 2.0 ambient (outdoor) concentration file:

SpeciesFile ContamW 2.0
free-text description
1/1<TAB>1/2<TAB>1                 start date, end date, number of species
sarin                             one species name per line
!Date<TAB>Time<TAB>sarin
1/1<TAB> 0:00:00<TAB>0.0023254    rows: date, time, one mass fraction (kg/kg) per species
1/1<TAB>24:00:00<TAB>0.0

Values are interpolated linearly between rows, and a day's 24:00:00 is the next day's 00:00:00. ContamX uses the file only when its species match the project's; this reader refuses a mismatch and names both lists.

outdoor = read_ctm("outdoor.ctm")
inputs = outdoor.inputs(model)      # writes "species.x_boundary" at every step of simulate